Roof louvers aka roof cans which is best.
Intake versus ridge roof vents.
However if you were only going to install 3 or 4 the turbines would be more affordable to you.
You do not want a box vent acting as in intake vent b c it will suck air in and can also suck in rain or snow with it.
That means roof ridge vents.
We added the edge vent for proper intake and replaced the roof louvers with continuous shinglevent ii ridge vents said jason vogen ceo of elite.
The soffit vents act like the air intake for the home.
The problem with gables is they short circuit the air flow paulcp writes.
Roof box vents and continuous ridge vents are separated by a few differences and deciding which one to put on your roof depends on which better fits the type and situational roof you have.
The whole point to a ridge vent is that it takes air from all along the bottom of the roof line and exits it out the top kind of like a toilet.
What are the cons.
Roof ridge vents provide a costly system of ventilation that may not be suitable for the checkbooks of some homeowners.
Which ultimately will increase the longevity of the roof and the life of his home.
The winner by far is a concealed ridge vent over roof louvers.
If it fits in your budget i would highly recommend upgrading as it will not only make your new roof look nicer it will save you money on cooling in the summer months.
But the ridge vent maintenance and running cost is a lot less than for turbines when.
The reason you do not mix them is that the ridge vent can turn the box vents into intake vents.
Even without soffit vents a ridge vent is much more effective than gable vents paulcp thinks hammer is right.
Most building codes define a balanced ventilation system as one square foot of ventilation for every 300 square feet of attic floor space with half the ventilation represented by intake vents and half by by exhaust vents.
If you were to install about 40 feet of roof ridge vent the area would span up to 10 turbines in this case 10 turbines would cost you substantially more to purchase and install.
If the amount of intake ventilation cannot match the entire 40 feet of ridge vent consider reducing the width of the ridge vent slot thereby reducing the vent s nfa per linear foot to accommodate the amount of intake nfa available.
In this back by popular demand article see the difference between roof box vents and continuous ridge vents.
This option might be the updated system which most newer homes use but if you have an older home then you might need the soffit vents too.
For every square inch of ridge exhaust vent you must balance it with at least one square inch or more of soffit intake vent.
This can cause a leak.
The homeowner has seen a drastic improvement in the air temperature in the upper level of his home.